Narrated in EnglishVer la versión en español →
Advanced FEA & integrity
Steel remembers
Anchor impact and dent on a subsea pipeline · narrated
- Duration
- 1:25
- Year
- 2026
The case
A 2 t anchor hits a 12 in X65 subsea pipeline, unpressurized at that moment, with 11.9 kJ. The wall goes in 34 mm under 549 kN; with the anchor gone the dent springs back to 25.5 mm, and with 180 bar in service it shrinks to 21 mm. The plastic strain does not go back: 22.0 % under the anchor, 22.2 % after rerounding (local peak in the model). An in-line inspection finds the smallest dent of the three.
Topics
- Pipeline dents
- Elastic-plastic FEA
- Narrated explainer
Basis. Generic synthetic case built for this piece. No client data. Not a design verification.
Need this analysis on your project?
The same method applies to your geometry, your loads and your acceptance criteria.
Discuss a project